Triple C single
For technical specification and support, please visit our public website
|
Schematics | PCB layout | Part list | | | | | | | | | | | | | Service-notes | | | |
Software | Please refer to our public webpage for latest software version | |
GUIDES | | | |
|
PERFORMANCE DATAConditions: In level: 0dB*, Out level: 0dB, Analog in 48KHz, Digital in gain 0dB, Input RNG, Output RNG 20dB, Bypass all ON. Generator: | DUT notes: | Audio Precision analyzer setup: | | | | | Result | | | Muted: L | | Noise | | <-76 | dBu | un-wtd 22-22k | Muted: R | | Noise | | <-76 | dBu | un-wtd 22-22k | 23 | dBu, 2kHz | | THD+N | | <0.003 | % | un-wtd 22-22k | | | | @ Level | | + 20 | dBu | +/- | dB | 23 | dBu, 2kHz | | THD+N | | <0.003 | % | un-wtd 22-22k | | | | @ Level | | +20 | dBu | +/- | dB | 24 | dBu, 2kHz | | THD+N | | <0.070 | % | un-wtd 22-22k | | | | @ Level | | +0.0 | dBu | 0.5 | dB | 24 | dBu, 20Hz | +/- 1dB | Level | | +20 | dBu | rel. 1kHz | 24 | dBu, 20kHz | +/- 1dB | Level | | +20 | dBu | rel. 1kHz | | | | | | | | | 24 | dBu, 1kHz | | Level | | +20 | dBu | 1 | dB | | | | Level | | | dBFS | | dB |
Self test menuEnter the self test menu. Power on while pressing "ENVELOPE MODE / SOFTLIM". - Loop the midi in/out with a midi cable.
Choose "Front test" by pressing "MENU" and run through the test procedure. Power off and on.
Reset the unit: - Power on the unit while pressing "MENU" to enter the system menu.
- Choose "Reset system parameters" press "MENU" and wait until its done.
- Find the latest software and upload it (Midi speed set to 31250).
- Power off the unit.
Sound check!Connections: Connect the power cable. Connect pedal jack to EXTERNAL CONTROL IN. Connect the MIDI OUT to MIDI IN and MIDI THRU to MIDI IN in the panel. Connect DI(S/PDIF) to Fin96-controllers DUT-stik and DO(S/PDIF) to the Fin96(DI) in the panel. Connect the MAIN OUT to "Input 1" in the panel. The MAIN IN connects to "Output 1" in the panel NOTE: Do not connect the SIDE HAIN IN AND DIRECT OUT. - Adjust the Finalizer 96 like this: Input:S/PDIF Mode: Mode48 Fin96-controller set to "CD dig out".
Connect a CD player to the unit listen if there is a signal playing through the device. Check if the device locks to the 44.1khz and check if the in and output matches with the Fin96. Press the pedal jack and see/hear if the bypass goes on and off and if the MIDI LED in the panel does blink. Disconnect the MIDI IN or the MIDI OUT. Press the MENU button and choose I/O and choose Digital and press MENU. Check if the signal locks to the Fin96 listen to the signal at all levels and listen for any bad sound. Repeat for Analog test. Change between 48khz and 44.1khz and notice if the Fin96 locks to it and listen too any bad sound.
Pause the CD player. Set the INPUT and the MAKE UP GAIN level to max. You can hear a weak click sound when passing the +6dB on the INPUT pot meter. Check the pot meter for high noise and crackling sounds if so the pot meter may be defect. Adjust the INPUT and the MAKE UP GAIN to low settings and start the CD player.
- Enter the self test menu
- Enter the front test and follow the procedure make sure all is working ok.
- Feed a signal through the unit and knock test it, listen for any sound changes, click or noise sounds.
- Power off and on a couple of times to ensure it starts up properly every time and check if the latest software is installed.
- Finish
|